Warming up to data center efficiency depends on how you cool off
A data center hosting critical IT equipment requires an efficient air flow management strategy to ensure the overall efficiency and sustainability of the data center. Hence, a significant part of the data center’s power is consumed to assure that the servers and equipment are cooled with advanced cooling technologies and optimal cooling solutions. This guarantees equipment protection and empowers the data center to meet the uptime goals in a cost-efficient manner.
Need
for temperature regulation
Maintaining the
right temperature and Humidity is quite a struggle for data center designers
and managers. However, it is critical to ensure a maintained
temperature/Humidity to ensure Equipments are working at Optimal condition. The
airflow and temperature regulation problems occur due to varying density
requirements of each cabinet in the data center. Issues in maintaining the
temperature also occur due to improper cabling and patching work. As it is
understood that with every watt of power consumed, it transforms into heat.
Facts
and real-time problems that can’t be ignored!
In an attempt to appropriately redirect the hot air through an exhaust,
the data center uses cooling solutions to physically separate cold and hot aisles containment by
installing an efficient airflow management system. However, the airflow
management and containment systems also have disadvantages that can result in a
hot spot effect. Such an effect can be identified with temperature fluctuations
in certain areas of the data center.
Here it must be
mentioned that similar to overheating, overcooling too is damaging for the data
center efficiency due to the following reasons.
- It
can cause humidity resulting in equipment failure
- It
can result in excess energy expenses
The actual
percentage of the real-time design load being used decides the energy
efficiency of the data center. This is the reason why organizations operate on
(80 to 85) % of the design load. Due to high power density, there are couple of
examples where the racks are consuming 28~44 kW of Power. Some organizations
prefer over-sized design capacity to mitigate risk, however it reduces the
energy efficiency of the data center.
Netrack’s
offering
Netrack designed
the airflow management solution after analyzing the issues faced by the data
centers to enhance their cooling efficiency.
Let’s look at the
following issues
- Raised
floor: Cold air leakage and cable damage due to uneven cutting of the
tiles
- Within
the rack: Hot cold air mixing due to irregular cutouts for passing the
cables
- Inside
The rack: Intra and Inter rack cabling issues, Side airflow devices need
proper managing.
- Arround
the Rack: Results in mixing hot and cold air within a rack.
Netrack’s solution
for the issues.
- Brush
Tile helps to reduce cold air leakage and cable damage.
- Plinth
air seal kit, blanking panels, and brush modules ensures that the hot and
cold air is not mixed.
- Brush
Module ensures cold air is not escaped while pulling the cables and also
will prevent the cable damage.
- Air
Seal Kit blocks unwanted cold or hot air from entering through the vent
and ensures cold air suction from the front while exhaustion of hot air
happens at the back.
- Blanking
Panels are filler panels or rack spacers placed within server racks to
prevent the mixing of hot and cold air.
Hence, efficient airflow management, containment
solution, and reduced energy consumption can ensure the efficient functioning
of a data center.